Skip to content
Tactiverge

Circuit fundamentals

RC time constant

Also called: tau = RC · capacitor charging · RC filter

Definition

When a capacitor charges or discharges through a resistor, the voltage changes exponentially with time constant τ = R × C.

Picture it

After one time constant a charging capacitor reaches about 63 % of the final voltage; after five, it is within 1 %. Bigger resistance means a trickle of current; bigger capacitance means a bigger bucket. Both slow things down, which is why RC circuits are used for debouncing and smoothing.

The maths

τ = R × C
Charging: V(t) = V_s × (1 − e^(−t/τ))
Discharging: V(t) = V_0 × e^(−t/τ)
SI units used in this entry
QuantityUnitSymbol
timeseconds
resistanceohmΩ
capacitancefaradF
voltagevoltV

Worked example

A 10 kΩ resistor charges a 100 µF capacitor from a 5 V supply. What is τ and the voltage after 1 s?

  1. τ = 10000 × 100 × 10^-6 = 1 s
  2. V(1 s) = 5 × (1 − e^-1) = 5 × 0.632 = 3.16 V

Answerτ = 1 s; about 3.16 V after 1 s.

✓ The 2 numbers in this answer are recomputed from scratch by an automated test.

Common misconceptions

  • Misconception: The capacitor is not 'full' after one τ; it is only 63 % of the way.
  • Misconception: Ω × F really is seconds; forgetting the µ prefix gives a time a million times too long.