Skip to content
Tactiverge

Circuit fundamentals

PWM average voltage

Also called: pulse-width modulation · duty cycle · analogWrite

Definition

Pulse-width modulation switches a signal fully on and off quickly; the fraction of time it is on, the duty cycle, sets the average voltage delivered.

Picture it

A motor or LED is too slow to follow fast switching, so it responds to the average. 25 % on-time from a 12 V supply looks like 3 V. Because the switch is either fully on or fully off it wastes little power, unlike a resistor dropping the extra voltage.

The maths

duty D = t_on / T
V_avg = D × V_supply
f = 1 / T
SI units used in this entry
QuantityUnitSymbol
voltagevoltV
percentageper cent%
frequencyhertzHz
timeseconds

Worked example

A 12 V motor driver runs at 20 kHz with a 40 % duty cycle. What is the period, the on-time and the average voltage?

  1. T = 1 / 20000 = 0.00005 s = 50 µs
  2. t_on = 0.40 × 50 = 20 µs
  3. V_avg = 0.40 × 12 = 4.8 V

AnswerT = 50 µs, on for 20 µs, average 4.8 V.

✓ The 3 numbers in this answer are recomputed from scratch by an automated test.

Common misconceptions

  • Misconception: PWM is not a true analogue voltage; a scope shows full-height pulses.
  • Misconception: Changing PWM frequency does not change the average; duty cycle does.