First-order systems and the time constant

A first-order system obeys tau times dy/dt plus y equals K times u. K is the static gain, the final change in output per unit of input, and tau is the time constant. After a step input the output follows y equals K u times one minus e to the minus t over tau: it covers about 63 per cent of the change in one time constant, 86 per cent in two and gets within 2 per cent after about four. Cooling drinks, heating ovens, charging capacitors and motor speeds all behave this way to a first approximation. Reading tau and K off one measured step response is often the first step in designing a controller.

Why it mattersA 3D printer's heater control starts from the nozzle's measured time constant, which says how quickly it can possibly respond.