First-order system and time constant

Also called: first-order lag · time constant · τ · exponential approach

Definition

A first-order system responds to a step by approaching its new value exponentially; its time constant τ is the time to cover 63.2 % of the change.

Picture it

Heating a room, spinning up a motor against friction, charging a capacitor: each slows down as it nears the target, because the driving difference shrinks. Every τ removes 63.2 % of what is left. After about 4τ it is within 2 %.

The maths

τ dy/dt + y = K u
step response: y(t) = K u (1 − e^(−t/τ))
SI units used in this entry
QuantityUnitSymbol
timeseconds
ratiodimensionless1

Worked example

A motor's speed responds as a first-order system with τ = 0.25 s and final speed 200 rad/s. What speed is reached after 0.5 s?

  1. y(0.5) = 200 × (1 − e^(−0.5/0.25)) = 200 × (1 − e^−2)
  2. = 200 × 0.8647 = 172.9 rad/s

AnswerAbout 172.9 rad/s.

✓ The number in this answer is recomputed from scratch by an automated test.

tune it

PID step response

Dashed line: setpoint 1. Solid line: output y over 8 s.
Overshoot 0 % · 2 % settling time 5.17 s · final value 0.994

Simplified model: plant τ·dy/dt = −y + u with τ = 0.5 s and gain 1, forward-Euler steps of 0.01 s, derivative on measurement. Real plants add delay, noise and saturation.

Common misconceptions

  • Misconception: A first-order system never overshoots a step; if yours does, it is not first-order.
  • Misconception: τ is not the time to finish; it is the time to get 63 % of the way.