Tactiverge Nexus · virtual engineering environment
Sensors, code and machines, wired into one system.
Every lab you have used so far studies one part. Nexus joins them: a noisy thermometer feeds a Bench-8 program, the program drives a heater, the heater warms a greenhouse, and the greenhouse changes what the thermometer reads next. You design the loop, run it, measure it and find out why it misbehaves.
Five modes, five ways of thinking
Not the same task made harder. Each mode asks a different engineering question of the same system. Levels describe what you can do, not your age.
- Level 1ExplorerCause and effectConnect a few big blocks, predict what will happen, run it and explain what changed.
- Level 2BuilderRules and debuggingTurn sensor readings into decisions with thresholds and hysteresis, then debug rules that misbehave.
- Level 3InnovatorIntegration to a specificationIntegrate a Bench-8 program, sensing and mechanisms to hit quantitative targets.
- Level 4Systems EngineerDynamics and trade-offsTune controllers against the system's time constant and trade energy against comfort against actuator wear.
- Level 5Research EngineerEvidence under uncertaintyRun seeded repeated trials, compare approaches with mean ± standard deviation, state limitations and export the evidence.
Projects
- 25 supported components · 5 modesIntelligent GreenhouseKeep the seedlings alive through a cold night, on a budget.Open the project →
- 11 supported components · 5 modesAutomated Sorting SystemTeach a conveyor to tell red plastic from everything else.Open the project →
- 15 supported components · 5 modesVirtual Robotic ArmPoint a two-joint arm at a target, then make it fast and steady.Open the project →
It checks your engineering before it runs
Every port carries a quantity and a unit. Wire a temperature into a power input and Nexus refuses, and tells you why. Every check comes with the engineering reason behind it.
- Incompatible quantities. You cannot feed one kind of physical quantity where another is expected: a temperature is not a power, just as 5 metres is not 5 seconds. Dimensional analysis catches this whole class of mistakes before any number is computed.
- Same quantity, different units. The quantities match, but the numbers would be misread: 20 °C is 293.15 K. Unit mix-ups like this have destroyed real spacecraft.
- Required input not connected. This block needs that signal to compute anything. With nothing connected its output would be undefined.
- Algebraic loop. These blocks form a loop in which each one needs the others' outputs at the same instant, with no memory anywhere to break the circle. There is no well-defined order to compute them in, and the 'answer' would have to be solved for, not simulated.
- Run would be unbounded. Duration ÷ step would need more steps than Nexus allows in one run. Long runs freeze the browser and do not teach more than a coarser step would.
- Numerical instability. A value grew far outside any physically sensible range. This usually means the numerical method is unstable at this time step (explicit Euler is only stable when the step is smaller than about twice the system's time constant) or a gain is so high the loop explodes.
- Value became NaN or infinite. A calculation produced 'not a number' or infinity (for example dividing by zero). Every later value would be garbage, so the run stops here.
- Impossible state change. A block's state jumped in a way its physics forbids (for example a servo moving faster than its rate limit). The model cannot be trusted past this point.
- Program never finished. The Bench-8 program used up its cycle budget for one sample without reaching HALT, so it produced no fresh output. Embedded programs must finish each control cycle on time, or the plant runs uncontrolled.
33 components
- Data sourcesStep · Ramp · Sine wave · Recorded profile · Schedule
- SensorsTemperature sensor · Distance sensor · Light sensor
- ProcessorBench-8 processor
- Digital logicComparator · Logic gate · NOT · Schmitt trigger · Relay driver
- ControllersOn/off controller · P controller · PI controller
- MathsGain · Sum · Moving average · Unit delay · Unit converter · Inverse kinematics
- MechanismsHeater · Fan · Vent motor · Joint servo
- Environment modelsGreenhouse · Conveyor and diverter · Two-link arm
- VisualisationMeter · Plot channel · Event log
Simplified on purpose. These are educational models with their assumptions shown on every block, not engineering-grade simulators or digital twins. Every run is deterministic: the same system and seed always give the same result. The greenhouse model is the same one as Build 007 and is tested against it.
Safety: Nexus never connects to physical hardware. No USB, serial or Bluetooth access; everything runs on your own device.
Sandbox
A greenhouse with a rule that misbehaves, to get you started. Add blocks from the library, wire outputs to inputs, press Run. Your work stays in this browser unless you export it.
Content status: technically checked (automated tests of every component, the validator and the engine, including a cross-check against the Build 007 greenhouse model). Not yet reviewed by an educator.