TactivergeLite

Lite / Engineering Complex Systems / Week 14

From overshoot to ζ and back

A spec says 'no more than 5 % overshoot'. What damping ratio does that demand, before you touch a single gain?

About 35 min · 3 goals · Checked by automated tests · Full interactive version

Why should I care?

Specifications are written in metrics (overshoot, settling time); designs are made in parameters (ζ, ωn, gains). These formulas translate between the two, so you can design on paper first and simulate to confirm.

Predict

Halving ζ from 0.6 to 0.3: what happens to the overshoot?

  1. It roughly doubles
  2. It goes from about 9 % to about 37 %
  3. It halves
  4. No change
Guess first, then reveal

%OS(0.6) ≈ 9.5 % and %OS(0.3) ≈ 37 %. The relationship is strongly nonlinear: halving ζ roughly quadruples overshoot here.

Discover

For ζ = 0.2, 0.43, 0.6 and 0.8, compare the formula and simulation columns for overshoot and peak time. Then find the ζ that gives 5 % overshoot by sliding, and check it against the derivation.

What the interactive shows (text version)

The mass–spring–damper table lists formula and simulation values side by side. At ζ = 0.43 both show about 22 % overshoot; at ζ = 0.69 both show about 5 %. Peak times agree to within a few milliseconds.

You can also open the interactive on the full site when you have a faster connection.

Understand

Overshoot depends only on ζ

%OS = 100·exp(−ζπ/√(1 − ζ²)). Landmarks: ζ = 0.2 → 53 %, 0.4 → 25 %, 0.5 → 16 %, 0.6 → 9.5 %, 0.7 → 4.6 %, 0.8 → 1.5 %. Memorise ζ = 0.5 → 16 % and ζ = 0.7 → 5 % and you can sanity-check most designs.

Timing depends on ωn too

Peak time tp = π/(ωn√(1 − ζ²)). The 2 % settling estimate ts ≈ 4/(ζωn) comes from the envelope e^(−ζωn t) dropping to e^(−4) ≈ 1.8 %. It is rough: good to roughly 10–20 % for light damping, poor near ζ = 1 and meaningless above it.

Spec to parameters

A spec 'OS ≤ 10 %, ts ≤ 2 s' becomes: ζ ≥ 0.59 (from the inverse formula) and ζωn ≥ 2 s⁻¹. Pick ζ = 0.6, then ωn ≥ 3.3 rad/s. Now you know what the closed loop must look like before you choose gains.

Explain it another way

Intuitive

ζ is a knob labelled 'how much it overshoots'. ωn is a separate knob labelled 'how quickly everything happens'. A spec tells you where each knob must sit.

Technical

The formulas are exact for the standard form ωn²/(s² + 2ζωn s + ωn²). Real loops with zeros, extra poles, delay or saturation deviate; treat the formulas as design starting points and verify in simulation.

Mathematical

ζ = 0.456 for 20 % overshoot: ln 0.2 = −1.609, √(π² + 2.590) = 3.530, ζ = 1.609/3.530 = 0.456.

Applied

Lift levelling: overshooting the floor by even 5 mm is a trip hazard, so the design aims for ζ near or above 0.8 in the levelling phase and accepts a slightly slower approach.

Derivation: Using the overshoot formula in both directions
  1. For an underdamped second-order step response, the first peak is at tp = π/ωd with ωd = ωn√(1 − ζ²).

  2. Substituting tp into x(t) = 1 − e^(−ζωn t)·(cos ωd t + (ζωn/ωd)·sin ωd t): cos(π) = −1 and sin(π) = 0, so x(tp) = 1 + e^(−ζωn·π/ωd).

  3. So the fractional overshoot is OS = exp(−ζπ/√(1 − ζ²)). It depends only on ζ.

  4. To invert, take logs: ln OS = −ζπ/√(1 − ζ²). Square and rearrange: ζ = −ln OS / √(π² + (ln OS)²).

  5. Example: OS = 0.05 gives ln OS = −3.00 and ζ = 3.00/√(9.87 + 8.97) = 0.69. A '≤ 5 %' spec needs ζ ≥ 0.69.

Worked example 1

A spec requires OS ≤ 20 % and peak time ≤ 0.5 s. Find the minimum ζ and the minimum ωn.

ζ ≥ 0.456 (computed above). At ζ = 0.456, tp = π/(ωn√(1 − 0.208)) = π/(0.890·ωn) ≤ 0.5, so ωn ≥ 7.06 rad/s.

Worked example 2

ζ = 0.5 and ωn = 4 rad/s. Predict overshoot, peak time and 2 % settling.

%OS = 16.3 %. ωd = 4√0.75 = 3.46 rad/s; tp = π/3.46 = 0.91 s. ts ≈ 4/(0.5 × 4) = 2.0 s.

Common mix-ups

Practice

Practice, not a test. Answers are checked on our server; a wrong answer gets a hint and another try. Nothing is saved.

%

%

s

Practice 6. When is ts ≈ 4/(ζωn) a poor estimate?

Apply it

Turn this spec into ζ and ωn limits: 'overshoot ≤ 8 %, 2 % settling ≤ 1.5 s, peak time ≤ 0.6 s'. Pick one (ζ, ωn) pair that meets all three and confirm it in the mass–spring–damper diagram.

Reflect

Why is it useful to know the required ζ before you start adjusting controller gains?

Write your answer on paper or in your own notes. Lite never stores what you write.

← Reading a step response like an engineerStop on the floor: specs in practice →