TactivergeLite

Lite / Engineering Complex Systems / Week 12

The time constant: 63 % and counting

Why do engineers quote 63 % rather than half when they say how fast something heats up?

About 35 min · 3 goals · Checked by automated tests · Full interactive version

Why should I care?

First-order models describe a huge range of systems well enough to design with: heaters, motors, tanks, RC filters, sensors. Two numbers, K and τ, tell you where it will end up and how long it will take. Engineers use them every day.

Predict

A first-order system takes 2 s to reach 63 % of its final value. Roughly when is it within 2 % of the final value?

  1. About 4 s
  2. About 8 s
  3. About 20 s
  4. Never
Guess first, then reveal

About 4τ = 8 s (more precisely 3.9τ ≈ 7.8 s). Each extra τ removes 63 % of what's left, so the last few per cent take the longest.

Discover

In Explore mode, set K = 2, τ = 1.5 s, u = 1. Check the curve crosses the 63 % line at τ. Then double τ, then double K: describe in one sentence each what changes and what doesn't.

What the interactive shows (text version)

The step responder draws a curve rising from zero towards K times u. A dashed line at 63 % of the final value meets the curve at t = τ, and a second marker at 4τ shows it within 2 % of the final value. Doubling τ stretches the curve horizontally; doubling K stretches it vertically.

You can also open the interactive on the full site when you have a faster connection.

Watch (optional)

Watch for: Note the difference between the transient part and the steady-state part of a response; in the first-order solution, which term is which?

Defines transient and steady-state response and the vocabulary used to describe them.

“Intro to Control - 9.1 System Time Response Terms” by Engineering with Prof. Kim (opens YouTube; streaming video uses a lot of data)

The video is optional. Everything you need is in this lesson's text.

Understand

Two numbers describe it all

In τ·dy/dt + y = K·u, the static gain K is how much the output changes per unit of input once everything settles. The time constant τ (seconds) is how quickly it gets there. Change K and the curve stretches up; change τ and it stretches sideways; the shape never changes.

Landmarks to sketch with

After 1τ: 63 % of the change. 2τ: 86 %. 3τ: 95 %. 4τ: 98 %. 5τ: 99.3 %. The slope at the start is (y∞ − y₀)/τ: if it kept that rate, it would arrive in exactly one τ. Those numbers let you sketch any first-order response in seconds.

Time constants are physical

τ is a storage size divided by a flow rate. For an RC circuit τ = R·C. For a heated object τ = (thermal mass)/(heat-loss coefficient). Bigger storage or slower leakage means a longer τ. That is why a thick pot takes longer to boil than a thin one.

Explain it another way

Intuitive

The system always closes a fixed fraction of the gap per unit time. Close to the target there's little gap, so it moves slowly. Like a nervous parker edging into a space.

Technical

First-order LTI: transfer function K/(τs + 1), single real pole at s = −1/τ. Step response y(t) = Ku(1 − e^(−t/τ)), initial slope Ku/τ, 2 % settling time τ·ln 50 ≈ 3.91τ.

Mathematical

y(t)/y∞ = 1 − e^(−t/τ). Set it to f and solve: t = −τ·ln(1 − f). For f = 0.5, t = 0.693τ (the half-life); for f = 0.632, t = τ; for f = 0.98, t = 3.91τ.

Applied

Electric kettle: K ≈ 80 °C rise for full power, τ of a few minutes. A temperature sensor in a metal sheath might have τ = 5 s: it will read 63 % of a sudden change after 5 s, which matters if you're controlling a fast process.

Derivation: Solving the first-order step response
  1. Model: τ·dy/dt + y = K·u, with a constant input u applied from t = 0 and y(0) = y₀.

  2. At equilibrium dy/dt = 0, so the final value is y∞ = K·u. Define the remaining error e = y − y∞.

  3. Since y∞ is constant, de/dt = dy/dt, and the model becomes τ·de/dt = −e.

  4. Separate variables: de/e = −dt/τ. Integrate: ln|e| = −t/τ + const, so e(t) = e(0)·e^(−t/τ).

  5. Therefore y(t) = y∞ + (y₀ − y∞)·e^(−t/τ). From rest (y₀ = 0): y(t) = K·u·(1 − e^(−t/τ)).

  6. At t = τ the remaining error is e^(−1) ≈ 0.368, so 63.2 % of the change is done. At 4τ only e^(−4) ≈ 1.8 % is left: the usual 2 % settling estimate (exactly 3.91τ).

Worked example 1

K = 3, step u = 2, τ = 4 s, starting at rest. Find y at t = 4 s and at t = 8 s.

y∞ = K·u = 6. y(4) = 6(1 − e^(−1)) = 6 × 0.632 = 3.79. y(8) = 6(1 − e^(−2)) = 6 × 0.865 = 5.19.

Worked example 2

A probe starting at 20 °C is plunged into 80 °C water. τ = 5 s. What does it read after 10 s?

y₀ = 20, y∞ = 80. y(10) = 80 + (20 − 80)·e^(−2) = 80 − 60 × 0.135 = 71.9 °C.

Common mix-ups

Practice

Practice, not a test. Answers are checked on our server; a wrong answer gets a hint and another try. Nothing is saved.

s

Practice 4. You double K and keep τ. How does the time to reach 63 % of the final value change?
Practice 5. If a first-order response kept its initial rate of rise, when would it reach the final value?

s

Apply it

Make a cup of tea and log its temperature every minute for 20 minutes (or use any published cooling data). Plot T − T_room on a log scale. Is it a straight line? Its slope gives −1/τ. Report τ and how well a single exponential fits.

Reflect

Why is 'within 2 %' a more useful engineering target than 'at the final value'?

Write your answer on paper or in your own notes. Lite never stores what you write.

← Updating every state, one step at a timeRead the plant from its step response →