Lite / Intelligent Robotic Systems / Week 30
Week 30: Feedback control
This week you will
- Derive and use the steady-state error of proportional control, e = r/(1 + K·Kp).
- Measure rise time, overshoot, settling time and steady-state error, and tune PID to a specification.
- Explain what integral and derivative action add and what they cost, including windup.
Lessons
- Why P control always falls short · about 40 min
Turn the proportional gain up from 1 to 9 and the error shrinks from half the setpoint to a tenth. Why does it never reach zero? - Reading a step response · about 40 min
Two controllers both reach the target. One gets there in 0.3 s but overshoots by 40 %; the other takes 2 s and never overshoots. Which is better? - What I and D buy, and what they cost · about 40 min
Integral action wipes out the lift's levelling error. So why do engineers sometimes switch it off while the lift is moving?