Skip to content
Tactiverge

Build Night 8: The Intelligent Greenhouse

Facilitator kit · 60 minutes · week 16 of 36 · free to reuse with attribution

Status: proposed. No date is confirmed and this night has not taken place. Run it live only as a session scheduled and listed on /live/, with a host and an adult supervisor confirmed.

Based on BUILD 007

This night reuses BUILD 007: Design a Smart Greenhouse. Read its facilitator guide first: prep, misconceptions, level tasks with answer keys. This kit adds only what is new for the Build Night.

Timing

  1. 0–3 min(3)Welcome and room rules. Introduce the host and the adult supervisor by role. Cameras, microphones and chat stay off; questions go in the moderated box. Point to the worksheet.
  2. 3–10 min(7)Hook and opening demo. New demo: the vent opens and the thermostat struggles.
  3. 10–20 min(10)The real system. Heat balance, time constant τ = C/UA, on/off with hysteresis, P-only offset, integral action.
  4. 20–35 min(15)Guided experiment. BUILD 007 Level 3, the PI settling experiment, then P against PI in the greenhouse.
  5. 35–48 min(13)Design challenge. Least energy, plus the thermometer placement argument.
  6. 48–55 min(7)Share and moderated questions. Put each team’s result on screen without names. Ask what they traded away. Answer moderated questions.
  7. 55–60 min(5)Reflect and follow-up. Everyone writes one sentence: what would you design differently now? Introduce the follow-up activity and the next Build Night’s question.

Script

Hook

Someone left the vent open on a freezing night. Can your controller notice, keep the seedlings warm and not waste energy?

Opening demonstration

BUILD 007 has a run of show in /build/smart-greenhouse/guide/ but no scripted live demo, so this night adds one. Share /build/smart-greenhouse/ and run the night with the default thermostat. When the vent opens at 22:00, point at the temperature line: “Watch it fall. The heater clicks on, the line wobbles back… but not all the way. A thermostat is one decision, made over and over again. Tonight we make it a better decision.”

The technical question

Why does an on/off thermostat need a gap between its switch-on and switch-off temperatures, and why does proportional-only heating settle short of the setpoint on a cold night?

The real-world system

Commercial greenhouses run climate computers that control heating, vents, shading, irrigation and sometimes CO₂ from many sensors. The same loop of measure, compare, decide and act runs home heating, incubators and data-centre cooling, and each has to cope with noisy sensors and disturbances like an open door.

Guided experiment

Start at /build/smart-greenhouse/?level=3 · labs: Feedback control lab

  1. BUILD 007 Level 3: set the switch-on and switch-off temperatures and the smoothing so the seedlings survive the open vent.
  2. In the feedback lab (/playground/feedback/), run the guided experiment “How long until it settles?” with a PI controller.
  3. Back in the greenhouse (Level 4): swap to P control, then PI, and record where the temperature settles each time.

Design challenge

BUILD 007’s challenge: keep the seedlings comfortable on the least energy. New for Build Night: each team decides where to put the thermometer in a real greenhouse and explains why a sensor in direct sun, or next to the heater, would fool the controller.

Say this about the model

The greenhouse is a single air temperature with illustrative heat capacity and losses; real greenhouses have sun, soil, plants and air movement.

Five levels, one night

LevelAdaptation
1 · ExplorerBUILD 007 Level 1: match the six parts to their jobs and order one turn of the loop.
2 · BuilderBUILD 007 Level 2: find the glitch and the mean in ten readings, then predict the settled temperature with the heat balance.
3 · InnovatorBUILD 007 Level 3: tune the on/off thermostat to survive the open vent.
4 · Systems EngineerBUILD 007 Level 4: P or PI at part power, on no more energy than the Build’s limit, with a predicted settling temperature.
5 · Research EngineerBUILD 007 Level 5: investigate a trade-off (for example, hysteresis gap against heater switches) across at least four runs.

Slide outline

  1. Slide 1: The Intelligent Greenhouse

    • Build Night title, week number, “Proposed programme” footer
    • Hook on screen: the vent is open and it’s freezing
    • Room rules: cameras, microphones and chat off; questions in the box
  2. Slide 2: Heat in, heat out

    • Warms when heat comes in faster than it leaks
    • τ = C / UA: 100 minutes in our greenhouse
  3. Slide 3: On, off, and the gap

    • Hysteresis stops constant clicking
    • Wider gap: fewer switches, bigger swings
  4. Slide 4: Proportional heating

    • Heat ∝ error
    • On a cold night it settles short
  5. Slide 5: Integral action

    • Keep adding up the error
    • The offset disappears
  6. Slide 6: Your turn next

    • Warm seedlings on the least energy, with a sensor you can trust.
    • One-sentence reflection on the worksheet
    • Where to find the follow-up and the next night

Verified videos

  • Thermostats: Cooler than you think! (Technology Connections) · https://www.youtube.com/watch?v=ZZC0SP02PqY
  • Heat Transfer: Crash Course Engineering #14 (CrashCourse) · https://www.youtube.com/watch?v=YK7G6l_K6sA

Embed only through youtube-nocookie.com, never autoplay, captions on.

Supervision checklist

  • ☐ Two adults minimum: the host (who teaches) and a named adult supervisor who stays for the whole session. The session does not start without the supervisor.
  • ☐ Learner cameras and microphones off; chat off. Questions come only through the moderated question box and are read aloud without names.
  • ☐ Links are posted on the session page, never in chat. Nobody is asked for personal details, photos, their school or their location.
  • ☐ No real hardware: every activity is a browser simulation or a paper design. Nobody opens, powers or modifies a real device during or after the session.
  • ☐ If anything worrying is said or seen, the supervisor follows the safeguarding procedure at /safeguarding/ straight away; the host pauses the activity if needed.
  • ☐ Session listed on /live/ with its host and supervisor confirmed before any learner is invited.
  • ☐ No real heaters, mains thermostats or greenhouse electrics: simulation and paper only.

Roles

  • Host: runs the demo, the slides and the experiment; calls time.
  • Adult supervisor (or co-host, with the supervisor present): moderates the question box and reads questions without names, watches the room and the safeguarding channel, posts links on the session page.

Accessibility accommodations

  • Slides use large, high-contrast text and never rely on colour alone. The host describes every chart and animation aloud.
  • Live captions switched on and tested before the session; the host reads each on-screen instruction aloud.
  • Every lab and Build works by keyboard, gives text readouts of its results and respects reduced-motion settings.
  • Worksheet available to print, in large print and as plain text; answers can be typed, drawn, or spoken to a helper.
  • A second screen is optional: following the host’s shared screen plus the worksheet is enough to take part.
  • Nobody has to finish in the hour: the follow-up activity is the same task, so extra time is built in.
  • Read temperatures aloud at key moments (22:00, 01:00, dawn); the chart has a text summary.

Rubric

CriterionDevelopingSecureExcellent
Science and mathsSays the heater warms the greenhouse.Explains hysteresis and the P-only offset.Uses the heat balance to predict where a controller settles.
EvidenceRuns the night once.Records a surviving design and the P against PI comparison.Compares designs on energy and comfort with the same disturbance.
Design decisionChanges settings by trial.Saves energy and names what was given up.Argues sensor placement from how heat moves.
CommunicationShares a result when prompted.Explains the result and one reason for it in their own words.Explains the result, the evidence and the trade-off clearly enough for a classmate to repeat it.

Feedback for learners, not a public score. No leaderboards.

Answer key (facilitator only)

  • τ = 0.6 MJ/K ÷ 100 W/K = 6,000 s = 100 minutes.

Follow-up activity

BUILD 007 Level 4 (smarter controller) or the Level 5 trade-off investigation.

Worksheet: The Intelligent Greenhouse

Name or nickname: ______________________ Level: ____________

  1. Put measure, compare, decide and act in order for the greenhouse.
  2. Why does a thermostat with no gap click on and off constantly?
  3. Why does P-only heating settle below the setpoint on a cold night?
  4. Record energy used and minimum temperature for your best design.
  5. Where would you put the thermometer, and where would you never put it?