Build Night 8: The Intelligent Greenhouse
Facilitator kit · 60 minutes · week 16 of 36 · free to reuse with attribution
Status: proposed. No date is confirmed and this night has not taken place. Run it live only as a session scheduled and listed on /live/, with a host and an adult supervisor confirmed.
Based on BUILD 007
This night reuses BUILD 007: Design a Smart Greenhouse. Read its facilitator guide first: prep, misconceptions, level tasks with answer keys. This kit adds only what is new for the Build Night.
Timing
- 0–3 min(3)Welcome and room rules. Introduce the host and the adult supervisor by role. Cameras, microphones and chat stay off; questions go in the moderated box. Point to the worksheet.
- 3–10 min(7)Hook and opening demo. New demo: the vent opens and the thermostat struggles.
- 10–20 min(10)The real system. Heat balance, time constant τ = C/UA, on/off with hysteresis, P-only offset, integral action.
- 20–35 min(15)Guided experiment. BUILD 007 Level 3, the PI settling experiment, then P against PI in the greenhouse.
- 35–48 min(13)Design challenge. Least energy, plus the thermometer placement argument.
- 48–55 min(7)Share and moderated questions. Put each team’s result on screen without names. Ask what they traded away. Answer moderated questions.
- 55–60 min(5)Reflect and follow-up. Everyone writes one sentence: what would you design differently now? Introduce the follow-up activity and the next Build Night’s question.
Script
Hook
Someone left the vent open on a freezing night. Can your controller notice, keep the seedlings warm and not waste energy?
Opening demonstration
BUILD 007 has a run of show in /build/smart-greenhouse/guide/ but no scripted live demo, so this night adds one. Share /build/smart-greenhouse/ and run the night with the default thermostat. When the vent opens at 22:00, point at the temperature line: “Watch it fall. The heater clicks on, the line wobbles back… but not all the way. A thermostat is one decision, made over and over again. Tonight we make it a better decision.”
The technical question
Why does an on/off thermostat need a gap between its switch-on and switch-off temperatures, and why does proportional-only heating settle short of the setpoint on a cold night?
The real-world system
Commercial greenhouses run climate computers that control heating, vents, shading, irrigation and sometimes CO₂ from many sensors. The same loop of measure, compare, decide and act runs home heating, incubators and data-centre cooling, and each has to cope with noisy sensors and disturbances like an open door.
Guided experiment
Start at /build/smart-greenhouse/?level=3 · labs: Feedback control lab
- BUILD 007 Level 3: set the switch-on and switch-off temperatures and the smoothing so the seedlings survive the open vent.
- In the feedback lab (/playground/feedback/), run the guided experiment “How long until it settles?” with a PI controller.
- Back in the greenhouse (Level 4): swap to P control, then PI, and record where the temperature settles each time.
Design challenge
BUILD 007’s challenge: keep the seedlings comfortable on the least energy. New for Build Night: each team decides where to put the thermometer in a real greenhouse and explains why a sensor in direct sun, or next to the heater, would fool the controller.
Say this about the model
The greenhouse is a single air temperature with illustrative heat capacity and losses; real greenhouses have sun, soil, plants and air movement.
Five levels, one night
| Level | Adaptation |
|---|---|
| 1 · Explorer | BUILD 007 Level 1: match the six parts to their jobs and order one turn of the loop. |
| 2 · Builder | BUILD 007 Level 2: find the glitch and the mean in ten readings, then predict the settled temperature with the heat balance. |
| 3 · Innovator | BUILD 007 Level 3: tune the on/off thermostat to survive the open vent. |
| 4 · Systems Engineer | BUILD 007 Level 4: P or PI at part power, on no more energy than the Build’s limit, with a predicted settling temperature. |
| 5 · Research Engineer | BUILD 007 Level 5: investigate a trade-off (for example, hysteresis gap against heater switches) across at least four runs. |
Slide outline
Slide 1: The Intelligent Greenhouse
- Build Night title, week number, “Proposed programme” footer
- Hook on screen: the vent is open and it’s freezing
- Room rules: cameras, microphones and chat off; questions in the box
Slide 2: Heat in, heat out
- Warms when heat comes in faster than it leaks
- τ = C / UA: 100 minutes in our greenhouse
Slide 3: On, off, and the gap
- Hysteresis stops constant clicking
- Wider gap: fewer switches, bigger swings
Slide 4: Proportional heating
- Heat ∝ error
- On a cold night it settles short
Slide 5: Integral action
- Keep adding up the error
- The offset disappears
Slide 6: Your turn next
- Warm seedlings on the least energy, with a sensor you can trust.
- One-sentence reflection on the worksheet
- Where to find the follow-up and the next night
Verified videos
- Thermostats: Cooler than you think! (Technology Connections) · https://www.youtube.com/watch?v=ZZC0SP02PqY
- Heat Transfer: Crash Course Engineering #14 (CrashCourse) · https://www.youtube.com/watch?v=YK7G6l_K6sA
Embed only through youtube-nocookie.com, never autoplay, captions on.
Supervision checklist
- ☐ Two adults minimum: the host (who teaches) and a named adult supervisor who stays for the whole session. The session does not start without the supervisor.
- ☐ Learner cameras and microphones off; chat off. Questions come only through the moderated question box and are read aloud without names.
- ☐ Links are posted on the session page, never in chat. Nobody is asked for personal details, photos, their school or their location.
- ☐ No real hardware: every activity is a browser simulation or a paper design. Nobody opens, powers or modifies a real device during or after the session.
- ☐ If anything worrying is said or seen, the supervisor follows the safeguarding procedure at /safeguarding/ straight away; the host pauses the activity if needed.
- ☐ Session listed on /live/ with its host and supervisor confirmed before any learner is invited.
- ☐ No real heaters, mains thermostats or greenhouse electrics: simulation and paper only.
Roles
- Host: runs the demo, the slides and the experiment; calls time.
- Adult supervisor (or co-host, with the supervisor present): moderates the question box and reads questions without names, watches the room and the safeguarding channel, posts links on the session page.
Accessibility accommodations
- Slides use large, high-contrast text and never rely on colour alone. The host describes every chart and animation aloud.
- Live captions switched on and tested before the session; the host reads each on-screen instruction aloud.
- Every lab and Build works by keyboard, gives text readouts of its results and respects reduced-motion settings.
- Worksheet available to print, in large print and as plain text; answers can be typed, drawn, or spoken to a helper.
- A second screen is optional: following the host’s shared screen plus the worksheet is enough to take part.
- Nobody has to finish in the hour: the follow-up activity is the same task, so extra time is built in.
- Read temperatures aloud at key moments (22:00, 01:00, dawn); the chart has a text summary.
Rubric
| Criterion | Developing | Secure | Excellent |
|---|---|---|---|
| Science and maths | Says the heater warms the greenhouse. | Explains hysteresis and the P-only offset. | Uses the heat balance to predict where a controller settles. |
| Evidence | Runs the night once. | Records a surviving design and the P against PI comparison. | Compares designs on energy and comfort with the same disturbance. |
| Design decision | Changes settings by trial. | Saves energy and names what was given up. | Argues sensor placement from how heat moves. |
| Communication | Shares a result when prompted. | Explains the result and one reason for it in their own words. | Explains the result, the evidence and the trade-off clearly enough for a classmate to repeat it. |
Feedback for learners, not a public score. No leaderboards.
Answer key (facilitator only)
- τ = 0.6 MJ/K ÷ 100 W/K = 6,000 s = 100 minutes.
Follow-up activity
BUILD 007 Level 4 (smarter controller) or the Level 5 trade-off investigation.
Worksheet: The Intelligent Greenhouse
Name or nickname: ______________________ Level: ____________
- Put measure, compare, decide and act in order for the greenhouse.
- Why does a thermostat with no gap click on and off constantly?
- Why does P-only heating settle below the setpoint on a cold night?
- Record energy used and minimum temperature for your best design.
- Where would you put the thermometer, and where would you never put it?