Skip to content
Tactiverge

Build Nights / Night 8

Night 8 of 18Week 16 · Term 2: Robots and systemsProposed · no date yet

The Intelligent Greenhouse

Someone left the vent open on a freezing night. Can your controller notice, keep the seedlings warm and not waste energy?

This night is part of a proposed programme. It has not been scheduled and has not taken place. When it is scheduled it will appear on /live/. You can do everything below on your own, today.

The big question

Why does an on/off thermostat need a gap between its switch-on and switch-off temperatures, and why does proportional-only heating settle short of the setpoint on a cold night?

In the real world

Commercial greenhouses run climate computers that control heating, vents, shading, irrigation and sometimes CO₂ from many sensors. The same loop of measure, compare, decide and act runs home heating, incubators and data-centre cooling, and each has to cope with noisy sensors and disturbances like an open door.

Try it: the guided experiment

Everything runs in your browser. No real hardware, ever.

  1. BUILD 007 Level 3: set the switch-on and switch-off temperatures and the smoothing so the seedlings survive the open vent.
  2. In the feedback lab (/playground/feedback/), run the guided experiment “How long until it settles?” with a PI controller.
  3. Back in the greenhouse (Level 4): swap to P control, then PI, and record where the temperature settles each time.

Start the experiment

The design challenge

BUILD 007’s challenge: keep the seedlings comfortable on the least energy. New for Build Night: each team decides where to put the thermometer in a real greenhouse and explains why a sensor in direct sun, or next to the heater, would fool the controller.

At your level

  • Level 1 · ExplorerBUILD 007 Level 1: match the six parts to their jobs and order one turn of the loop.
  • Level 2 · BuilderBUILD 007 Level 2: find the glitch and the mean in ten readings, then predict the settled temperature with the heat balance.
  • Level 3 · InnovatorBUILD 007 Level 3: tune the on/off thermostat to survive the open vent.
  • Level 4 · Systems EngineerBUILD 007 Level 4: P or PI at part power, on no more energy than the Build’s limit, with a predicted settling temperature.
  • Level 5 · Research EngineerBUILD 007 Level 5: investigate a trade-off (for example, hysteresis gap against heater switches) across at least four runs.

What the model leaves out

The greenhouse is a single air temperature with illustrative heat capacity and losses; real greenhouses have sun, soil, plants and air movement.

Watch first (optional)

Afterwards

BUILD 007 Level 4 (smarter controller) or the Level 5 trade-off investigation.

Everyone can take part

  • Slides use large, high-contrast text and never rely on colour alone. The host describes every chart and animation aloud.
  • Live captions switched on and tested before the session; the host reads each on-screen instruction aloud.
  • Every lab and Build works by keyboard, gives text readouts of its results and respects reduced-motion settings.
  • Worksheet available to print, in large print and as plain text; answers can be typed, drawn, or spoken to a helper.
  • Read temperatures aloud at key moments (22:00, 01:00, dawn); the chart has a text summary.

How the live session is kept safe

  • A host and a separate adult supervisor are there for the whole hour.
  • Your camera, microphone and chat stay off. Ask questions in the moderated box; they are read out without your name.
  • Nobody will ask for your personal details, photos, school or location.
  • Everything happens in a simulation or on paper. Never open or change a real device.

How we keep learners safe

Running this with a group? Open the printable facilitator kit.