Skip to content
Tactiverge

Digital multimeter

An instrument is only as good as the way it disturbs what it measures.

A digital multimeter measures voltage, current and resistance by turning each into a voltage, scaling it into range and converting it to a number. The engineering is in the details: a very high input resistance so it barely loads the circuit, protection so a mistake does not destroy it, and a converter that averages away noise.

  • 8 components
  • 2 worked equations
  • 1 live model
  • 2 safe experiments

1Exploded view

Take the digital multimeter apart.

plate 14 · digital multimeter, isometric, exploded

Tab to a numbered part (or tap it) to jump to its description. The same parts as a list:

  1. 1Front case
  2. 2Display
  3. 3Rotary selector
  4. 4Circuit board
  5. 5Converter chip
  6. 6Input jacks and fuse
  7. 7Battery
  8. 8Back case

2Major components

What every part does, and how.

  1. 01

    Front case

    The tough outer shell with a recessed display and dial.

    how →Shrouded jacks and a tough case are part of the safety design.

  2. 02

    Display

    Shows the reading, typically up to a few thousand counts.

    how →A '6000-count' meter can show 0 to 5999, so on a 6 V range it reads in 1 mV steps.

  3. 03

    Rotary selector

    Picks the function and range by switching resistor networks and paths.

    how →Wiper contacts on the back of the dial connect different parts of the circuit for each position.

  4. 04

    Circuit board

    Carries the input divider, protection parts and the converter.

    how →Precision resistors in a divider scale large voltages down into the converter's range.

  5. 05

    Converter chip

    Measures the scaled voltage, usually by integrating it over a fixed time.

    how →Integrating over a whole number of mains cycles averages out mains hum.

  6. 06

    Input jacks and fuse

    Where the test leads plug in; the current jack is protected by a fuse.

    how →Current is measured by passing it through a tiny known resistance (a shunt) and measuring the voltage across it.

  7. 07

    Battery

    Powers the meter's electronics and display.

    how →Only a few milliwatts are needed, so one battery lasts a long time.

  8. 08

    Back case

    Closes the meter and covers the battery compartment.

    how →The battery and fuse compartments are separate from the electronics for safety.

3System relationships

Where the energy and information go.

Each block is a part (or the world outside). Solid lines carry energy, dashed lines carry information, dotted lines carry matter such as water or air.

Circuit under testJacks + fuseSelectorfunction + rangeRange divideron the boardBatteryConverterintegratesDisplayCasefront and backBack case
Energy (solid)Information (dashed)Matter (dotted) Source Sense Decide Convert Output

Flows, in order

  • Circuit under test sends information to Jacks + fuseinformation: voltage
  • Jacks + fuse sends information to Range dividerinformation: protected input
  • Selector sends information to Range dividerinformation: which divider
  • Range divider sends information to Converterinformation: scaled voltage
  • Converter sends information to Displayinformation: counts
  • Battery sends energy to Converterenergy: a few mW
  • Display sends information to Caseinformation: reading
  • Case sends matter to Back casematter: enclosure

4Physical principles

The physics doing the work.

5Mathematical foundations

The equations, with real numbers in them.

Loading error

V_m = V · R_in / (R_s + R_in)

V_m
voltage the meter reads [V]
V
true open-circuit voltage [V]
R_s
source (Thévenin) resistance [Ω]
R_in
meter input resistance [Ω]

Worked example

  1. 1.V_m = 5 × 10 000 000 / (100 000 + 10 000 000)
  2. 2.V_m = 5 × 0.990 ≈ 4.950 V
  3. 3.Error = (4.950 − 5) / 5 ≈ −0.99 %
Reading
4.95 V
Error
-0.99 %

AssumesA 10 MΩ input, common for digital multimeters on DC volts. The source is modelled as a voltage behind one resistance.

Display resolution

step = range / counts

range
full-scale range [V]
counts
number of display counts [–]

Worked example

  1. 1.step = 6 / 6000 = 0.001 V
  2. 2.1 mV per count
Step
1 mV

AssumesResolution only; the stated accuracy is usually a percentage of the reading plus a few counts.

6Computing architecture

The computer inside the system.

A dedicated measurement chip with a small microcontroller core handles auto-ranging, averaging and the display.

  1. Layer 1

    Front end

    Protection, dividers, shunts and a precision reference.

  2. Layer 2

    Conversion

    An integrating converter a few times a second.

  3. Layer 3

    Firmware

    Auto-range, hold, min/max and battery monitoring.

7Engineering trade-offs

Every choice costs something.

  • Higher input resistance

    Gain:Less loading error on high-resistance circuits.

    Cost:More sensitive to picking up noise and stray voltages.

  • More counts

    Gain:Finer steps.

    Cost:Slower readings and more cost for the same accuracy.

  • Heavier input protection

    Gain:Survives mistakes and transients.

    Cost:Bigger parts, cost, and slightly more leakage.

8 · Try it · runs in your browser

Does the meter change the answer?

Change the circuit's source resistance and the meter's input resistance. See the reading and the loading error, and find when it starts to matter.

5.0 V
100 kΩ
10.0 MΩ
Meter reads
4.950 V
Loading error
-0.99 %
Current drawn by the meter
0.495 µA

Small, but bigger than many meters' stated accuracy.

-0.0-33.315,000Source resistance (kΩ)%

ModelThe meter is a pure resistance and the circuit is a voltage source behind one resistance (its Thévenin equivalent).

Go further with a related simulation: Voltage divider under load

9Suggested safe experiments

Things to try, safely.

Every experiment here is virtual or a household-safe observation. Never open real devices, batteries or power supplies, never work on mains electricity, and never look at the Sun.

  1. Observation

    Read a spec sheet

    1. Find a multimeter's published specification (manual or datasheet).
    2. Find its DC-volts input resistance and accuracy, such as ±(0.5% + 2 counts).
    3. Work out the worst-case error for a 5.000 V reading.

    Safety: Reading only. Measurements on real circuits are for supervised, low-voltage battery circuits only; never measure mains.

  2. Virtual

    Loading in the simulator

    1. In the demonstration, set a 10 MΩ meter.
    2. Find the source resistance that gives a 1% error.
    3. Repeat for a 1 MΩ meter.

    Safety: Runs entirely in your browser.