Encoder resolution → tool-tip uncertainty: experiment bench
Encoder resolution → tool-tip uncertainty
Propagate joint-encoder resolution to tool-tip error through the Jacobian, and check it with a seeded Monte Carlo experiment.
- 1. Ask
- 2. Hypothesise
- 3. Set up
- 4. Run
- 5. Record
- 6. Change one variable
- 7. Compare
- 8. Interpret
- 9. Limitations & save
If I change …, then … will …, because …
3 · Set up the parameters
Each extra bit halves the angle step 2π/2ⁿ.
1 more control appear at higher levels; until then it stays at the default value.
The seed fixes any random noise. Same parameters + same seed = exactly the same result, every time, on every computer.
6 · Change one variable
Your first run is the baseline. After it, change one thing at a time.
7 · Compare on a graph
5 · Run log
No runs yet.
Equations
Step q = 2π / 2ⁿ. A rounded reading is wrong by up to ±q/2.
Assumptions (always true in this model)
- Planar arm: everything happens in one flat plane.
- Rigid links and ideal revolute joints: no bending, backlash or play.
- Kinematics only: no masses, gravity or motor dynamics in this model.
- Distances in centimetres, angles in degrees on the controls (radians inside the maths).
- Quantisation errors are independent between joints and uniform on ±q/2 (true angle not aligned with the code wheel).
- First-order (Jacobian) propagation; it fails near singularities, which the Monte Carlo check exposes.
Text description of what the chart shows
A cloud of possible tool-tip positions caused by rounding each joint angle to the nearest encoder step. The plots show the x and y error of each Monte Carlo trial; the metrics compare the spread predicted by the Jacobian with the spread actually simulated, and the linearised worst case.
Did the result support your hypothesis? Use the numbers from the comparison table and link them to an equation.
Which assumptions could change your answer in the real world?
Export and save
Exports use the ticked runs (or every run if none are ticked). Your draft saves automatically in this browser only. The Journal is private to you.
Valid parameter ranges
| Parameter | Range | Default |
|---|---|---|
| Link 1 length L₁ | 5 to 40 cm | 20 |
| Link 2 length L₂ | 5 to 40 cm | 15 |
| Shoulder angle θ₁ | -180 to 180 ° | 30 |
| Elbow angle θ₂ | -180 to 180 ° | 50 |
| Encoder resolution | 4 to 16 bits | 8 |
| Monte Carlo trials | 100 to 5000 | 1000 |
Independent reference checks
L = 10 cm, (0°, 90°), 10-bit
Hand: J = 10·[[−1, −1], [1, 0]], σ = (2π/1024)/√12, Σ = 100σ²·[[2, −1], [−1, 1]], eigenvalues (3 ± √5)/2; worst case |J|·q/2 summed per axis.
Monte Carlo agrees
Same closed-form major axis; 5000 samples give a sample-sd uncertainty of roughly 1 %, so ±5 % is a fair band.
Checked automatically on every change to the code. Educational model, not engineering-grade.