Skip to content
Tactiverge

School/□ Systems Engineer/Week 16

More gain, less damping

On a first-order plant, cranking up P gain only helps. On a robot joint with inertia, it makes it shake. What's different?

About 35 min · 3 goals · Checked by automated tests

1.Why should I care?

This is the classic control trade-off: gain buys speed and accuracy but costs damping. Knowing exactly how much lets you choose a gain on paper, and see why almost every motion controller adds D.

  • ◇ Show that P control of a second-order plant raises ωn by √(1 + KKp) and divides ζ by √(1 + KKp).
  • ◇ Predict the overshoot that a given gain will cause.
  • ◇ Explain why derivative action is the natural fix.

2.Predict

A joint has ζ = 0.9 on its own. You close a P loop with KKp = 8. Roughly what overshoot do you expect?

Guess first. Being wrong here is how the surprise works.

3.Discover

Choose P, actuator limit None. Raise Kp from 1 to 15 and note the overshoot. The plant has ζ = 0.7 and K = 1: predict each overshoot from ζ/√(1 + Kp) before reading it.

Loading the interactive…

Can't use the interactive? Read a description instead

In the PID tuner with P control and no actuator limit, Kp = 1 gives a small overshoot. As Kp rises to 15, the response rises faster, settles closer to the set point and overshoots more, with visible ringing.

4.Checkpoint: guided practice

Check what you just discovered before going on. Hints appear after a wrong answer.

Practice 1

A second-order plant has ζ = 0.9 and K = 1. With Kp = 8, what is ζcl?

5.Understand

The algebra

Plant τ²ÿ + 2ζτẏ + y = K·u with u = Kp·(r − y) gives τ²ÿ + 2ζτẏ + (1 + KKp)·y = KKp·r. Matching to the standard form: ωn,cl = √(1 + KKp)/τ and ζcl = ζ/√(1 + KKp). The stiffness went up; the damping didn't.

What it feels like

Raising Kp is like fitting a stiffer spring to the joint: it springs back faster and harder, so it overshoots. The steady error still falls as 1/(1 + KKp). You trade accuracy against wobble.

Derivative action is extra damping

A D term adds a force proportional to velocity: exactly what a physical damper does. With u = Kp·e − Kd·ẏ, the ẏ coefficient grows from 2ζτ to 2ζτ + K·Kd, raising ζcl back up. That's why motion controllers are almost always PD or PID.

Explain it another way

P control is a spring tying the output to the target. A stiffer spring pulls it there faster but bounces more. D control is a shock absorber.

Worked example 1

Plant ζ = 0.8, K = 1. Which Kp gives ζcl = 0.4?

0.8/√(1 + Kp) = 0.4 → √(1 + Kp) = 2 → Kp = 3. Expected overshoot 25 %.

Common mix-ups

  • If P control overshoots, the gain is too high, full stop.
    ✓ Lowering gain is one fix; adding damping (D) keeps the speed and accuracy while removing the overshoot.

6.Practice on your own

Practice, not a test. Wrong answers get a hint and another try.

Practice 2

With ζcl = 0.3, what overshoot do you expect, in percent?

%

Practice 3 · a fresh version every time

An underdamped second-order system has damping ratio ζ = 0.32. What percent overshoot does its step response have?

%

Practice 4

When you raise Kp on a second-order plant, which stays the same?

Practice 5

Your P-controlled joint overshoots 35 %. Which change reduces overshoot while keeping the gain?

7.Apply it

In the PID tuner, find the largest Kp that keeps overshoot under 10 % with P only. Then add D and find how much more Kp you can use for the same overshoot. Report both.

8.Reflect

Concepts: Proportional control · Derivative action and damping · Stability, overshoot and delay