Lite / Independent Engineering Research / Week 36
Capstone: running the pilot
The pilot is not a sneak preview of your result. It is a rehearsal designed to fail early. What should it check?
Why should I care?
The pilot is the second half of the term project. Done well, it means your confirmatory runs will not be wasted by a broken metric, a missing seed or a run that takes three times longer than planned.
- Run a small pilot that tests the procedure, recording and analysis pipeline.
- Use pilot variability to confirm the sample size, without peeking at the effect.
- Revise the protocol and log every change.
Predict
Your pilot of 4 runs per condition shows the new method winning clearly. What should you do with this?
- Report it as the result
- Nothing: pilot effects are not evidence; use only its variance and procedural lessons
- Increase your SESOI to match
- Stop the study
Guess first, then reveal
Four runs give a very noisy effect estimate, and using it to adjust the plan would bias the confirmatory study. Use the pilot for procedure and σ only.
Discover
Run your pilot: two conditions, a few runs each, using your registered procedure exactly. Check: every run logged with seed and settings, metric computed by script, analysis pipeline produces a figure with an interval, time per run measured. Write down every problem you hit.
What the interactive shows (text version)
The rover Level 5 investigation records runs with chosen settings for a report. This lesson uses it for a small pilot: checking logging, metric scripts, the analysis pipeline and time per run, and measuring the spread of the primary metric.
Understand
Pilot checklist
Can every setting be changed as planned? Is every run logged (seed, settings, version, outcome, time)? Does the metric script handle failures? Does the full pipeline, raw data to figure, run with one command? How long does a run really take? What is σ for the primary metric?
Use σ, not the effect
Recompute the sample size with the pilot's σ and your registered SESOI. If n grows beyond feasibility, change the design (paired seeds, fewer conditions) and log it. Do not let the pilot's effect size change the hypothesis or the SESOI.
Keep pilot data separate
Store pilot runs in their own folder and exclude them from the confirmatory analysis. Report the pilot in the Methods: what it checked and what it changed.
Explain it another way
Intuitive
A fire drill tests the exits, not whether there is a fire.
Technical
Pilot-based effect estimates have large variance and, if used to select studies or thresholds, introduce bias; pilot variance estimates are less problematic and are what power analysis needs.
Applied
Industrial test campaigns run 'shakedown' tests before qualification tests for exactly this reason.
Worked example 1
Pilot σ = 0.35 m, SESOI 0.2 m, two independent groups. Runs per group for 80% power?
d = 0.2/0.35 = 0.571. n = 2 × (2.80/0.571)² = 2 × 24.0 = 48.0, so 49 per group (rounding up). With paired seeds the σ of differences may be much smaller, cutting n.
Common mix-ups
A successful pilot means the experiment will work.
✓ A successful pilot means the procedure works. Whether the hypothesis survives is what the confirmatory study is for.
Practice
Practice, not a test. Answers are checked on our server; a wrong answer gets a hint and another try. Nothing is saved.
Apply it
Term project, part 2: run your pilot, write a half-page pilot report (what was checked, what broke, σ, time per run), update the sample size, and commit a revised protocol with a deviation log.
Reflect
What did the pilot reveal that you would never have predicted?
Write your answer on paper or in your own notes. Lite never stores what you write.