The moving average, seen in frequency

Averaging the last four readings smooths a sensor beautifully. So why does it completely erase one particular frequency?

About 35 min · 3 goals · Checked by automated tests · Full interactive version

Why should I care?

The moving average is the most used filter in embedded code: one line, no multiplications. Its frequency response explains both its strength (it kills noise and specific interference) and its weaknesses (lag and leaky high frequencies), so you can choose M on purpose instead of by trial.

Predict

A 4-point moving average runs at 1 kHz. What happens to a 250 Hz sine?

  1. It passes unchanged
  2. It is halved
  3. It is removed completely
  4. It is doubled
Guess first, then reveal

250 Hz has a period of exactly 4 samples, so every window holds one whole cycle, which averages to zero. Nulls sit at fs/M = 250 Hz, 500 Hz… Find the dip in the response explorer.

Discover

Choose 'Moving average', low-pass. Set M = 4 and slide the test frequency to find the null. Change M to 8 and 2: where do the nulls go? Watch the step response: how many samples does it take to reach the top?

What the interactive shows (text version)

In the explorer, the 4-point moving average has gain 1 at 0, falls to about 0.77 at f/fs = 0.1, and reaches 0 at f/fs = 0.25 (a null), with a small bump after it. With M = 8 the first null moves to 0.125. The step response climbs in M equal steps to 1.

You can also open the interactive on the full site when you have a faster connection.

Understand

One line of code

y[n] = (x[n] + x[n−1] + … + x[n−M+1])/M. It is a finite impulse response (FIR) filter: an impulse affects exactly M outputs, then is forgotten. Random noise of standard deviation σ comes out with σ/√M, because independent errors partly cancel.

Nulls and side lobes

Its gain is 1 at DC and falls to exactly zero at fs/M, 2fs/M, …, with bumps (side lobes) in between: the first is about 0.22 for large M. Great for removing a known interference, like 50 Hz mains when fs/M = 50 Hz, but a mediocre general low-pass because the side lobes leak.

The price: lag

The output is centred (M − 1)/2 samples in the past. With M = 9 at 100 Hz that is 40 ms: fine for a thermometer, dangerous inside a fast control loop where delay erodes stability. Doubling M halves the noise power again but doubles the lag.

Explain it another way

Intuitive

Averaging the last few readings irons out quick jitters but makes the reading arrive late, like a crowd repeating what the person at the front said.

Technical

FIR filter with M equal taps of 1/M. Linear phase (constant delay), always stable, frequency response a periodic sinc ('Dirichlet kernel').

Mathematical

|H(f)| = |sin(πMf/fs)/(M·sin(πf/fs))|. Example: M = 4, f/fs = 0.1: sin(0.4π)/(4·sin(0.1π)) = 0.951/(4 × 0.309) ≈ 0.769.

Applied

Digital multimeters often average over exactly one mains period (20 ms in the UK), placing a null at 50 Hz and every harmonic, which is why they read steadily next to noisy wiring.

Derivation: The moving-average frequency response
  1. Input x[n] = e^{jωn} with ω = 2πf/fs. Output y[n] = (1/M)·Σ_{k=0}^{M−1} e^{jω(n−k)} = e^{jωn}·H, with H = (1/M)·Σ e^{−jωk}.

  2. That is a geometric series: H = (1/M)·(1 − e^{−jωM})/(1 − e^{−jω}).

  3. Factor out half-angles: (1 − e^{−jθ}) = e^{−jθ/2}·2j·sin(θ/2).

  4. So |H| = |sin(ωM/2) / (M·sin(ω/2))| = |sin(πMf/fs)/(M·sin(πf/fs))|, with a pure delay of (M − 1)/2 samples.

  5. It is 1 at f = 0 and 0 whenever Mf/fs is a whole number (other than multiples of M): nulls at f = fs/M, 2fs/M, …

Worked example 1

A 5-point moving average filters x = [2, 4, 6, 8, 10, 12]. Find y[4] and y[5].

y[4] = (2 + 4 + 6 + 8 + 10)/5 = 6. y[5] = (4 + 6 + 8 + 10 + 12)/5 = 8. A ramp comes out as the same ramp delayed by (5 − 1)/2 = 2 samples.

Common mix-ups

Practice

Practice, not a test. Answers are checked on our server; a wrong answer gets a hint and another try. Nothing is saved.

Hz

samples

Practice 5. Noise on a sensor is random with standard deviation 4 mV. Roughly what is it after a 16-point moving average?

Apply it

Your rover's 200 Hz IMU picks up 50 Hz interference from a motor driver. Choose M so a moving average nulls 50 Hz, compute its lag in milliseconds, and say whether that lag is acceptable for a balance controller that must react within 20 ms.

Reflect

When would you choose a moving average over a smarter filter, even knowing its weaknesses?