Fitting a cooling model to data

You have a column of temperatures from a cooling mug and one unknown number, k. How do you pull k out of noisy data, and how sure can you be?

About 45 min · 3 goals · Checked by automated tests · Full interactive version

Why should I care?

A model is not finished until its parameter comes from data. Fitting k turns a textbook equation into a prediction for your mug, your sensor or your circuit, and the linearising trick here is used across engineering whenever a model is exponential.

Safety: Use warm tap water, not boiling water, and keep the cup on a stable table. A thermometer is all you need; never put electronics in liquid.

Predict

You plot ln(T − Tₐ) against time for cooling data. What should you see if Newton's law holds?

  1. A curve that flattens out
  2. A straight line with negative slope −k
  3. A horizontal line
Guess first, then reveal

T − Tₐ = (T₀ − Tₐ)e^(−kt), so ln(T − Tₐ) = ln(T₀ − Tₐ) − kt: a straight line with slope −k. Curvature in that plot is evidence against the model or against your value of Tₐ.

Discover

Choose the mug of tea. Adjust k by eye until the curve runs through the points, and note your RMS error. Switch on the log view: are the points straight? Press Best fit and compare its k with yours. Which points scatter most in the log view, and why?

What the interactive shows (text version)

The decay-fit lab shows synthetic cooling data: 16 readings from 86 °C towards a 21 °C room over 60 minutes. A model curve with the chosen k is drawn through them. In log view, ln(T − 21) against time is close to a straight line with slope −k; late points scatter more. The least-squares fit gives k close to 0.042 per minute.

You can also open the interactive on the full site when you have a faster connection.

Understand

Linearise, then fit a line

Subtract the room temperature, take natural logs, plot against t. The slope of the best straight line is −k, the intercept ln(T₀ − Tₐ). A least-squares line through all points uses every reading, so it is far less sensitive to one bad reading than a two-point estimate.

Two-point estimate

From readings at t₁ and t₂: k = ln[(T₁ − Tₐ)/(T₂ − Tₐ)]/(t₂ − t₁). Quick and useful as a sanity check, but it rests entirely on two noisy numbers. Example: 86 °C at 0 min and 63.7 °C at 10 min in a 21 °C room give k = ln(65/42.7)/10 ≈ 0.042 per minute.

What distorts the fit

Noise near Tₐ: when T − Tₐ is small, a 0.5 °C error is a large fraction, so late points scatter wildly in the log view. Weight them less or stop the fit early. Wrong Tₐ: guessing the room 2 °C too low makes the log plot curve. Early evaporation from a hot drink cools it faster at first than the model allows.

Explain it another way

Intuitive

Fitting is turning a dial (k) until the model's curve lies as close as possible to all the dots at once. Taking logs turns the curve into a straight line, so the dial becomes a ruler's slope.

Technical

Least squares on yᵢ = ln(Tᵢ − Tₐ) against tᵢ: k̂ = −Σ(tᵢ − t̄)(yᵢ − ȳ)/Σ(tᵢ − t̄)². This minimises errors in log space, which overweights late, low readings compared with a direct nonlinear fit.

Mathematical

If each Tᵢ has error ε, the log has error ≈ ε/(Tᵢ − Tₐ): small near the start, large near the end. A weighted fit uses weights (Tᵢ − Tₐ)² to undo this.

Applied

Thermal engineers characterise a component's time constant exactly this way: heat it, log the cooling, fit k. That number then sets how long a sensor or a motor can be pushed before it overheats.

Worked example 1

Readings: 86 °C at t = 0, 63.7 °C at t = 10 min, room 21 °C. Estimate k and τ.

k = ln(65/42.7)/10 = ln(1.522)/10 = 0.420/10 = 0.042 per minute. τ = 1/k ≈ 23.8 min; half-life ≈ 16.5 min.

Common mix-ups

Practice

Practice, not a test. Answers are checked on our server; a wrong answer gets a hint and another try. Nothing is saved.

per min

min

Practice 3. You assumed Tₐ = 18 °C but the room was really 22 °C. What will the ln(T − Tₐ) plot show?

°C

s

Apply it

If you can do so safely, log a cup of warm (not boiling) tap water cooling for 30 minutes with a kitchen thermometer, every 2 minutes, and note the room temperature. Fit k by both methods. If you cannot, use the lab's synthetic set and say so in your write-up.

Reflect

Why do the latest readings scatter most in the log view, and what would you do about it?

Write your answer on paper or in your own notes. Lite never stores what you write.