Overshoot

Also called: percent overshoot · %OS · peak overshoot

Definition

Overshoot is how far a response goes past its final value, usually given as a percentage of the step size.

Picture it

A lift that sails past its floor and comes back has overshoot. For a standard second-order system, overshoot depends only on the damping ratio: less damping, more overshoot. Some applications tolerate none (a robot pressing on glass), others accept a little in exchange for speed.

The maths

%OS = (y_peak − y_final) / (y_final − y_initial) × 100
second-order: %OS = 100 × e^(−ζπ / √(1 − ζ²))
SI units used in this entry
QuantityUnitSymbol
percentageper cent%
ratiodimensionless1

Worked example

A second-order system has damping ratio ζ = 0.5. What overshoot do you expect? If a step to 2.0 m peaks at 2.3 m, what is the measured overshoot?

  1. %OS = 100 × e^(−0.5π / √0.75) = 100 × e^(−1.814) = 16.3 %
  2. Measured: (2.3 − 2.0) / 2.0 × 100 = 15 %

AnswerAbout 16.3 % predicted; 15 % measured.

✓ The 2 numbers in this answer are recomputed from scratch by an automated test.

tune it

PID step response

Dashed line: setpoint 1. Solid line: output y over 8 s.
Overshoot 0 % · 2 % settling time 5.17 s · final value 0.994

Simplified model: plant τ·dy/dt = −y + u with τ = 0.5 s and gain 1, forward-Euler steps of 0.01 s, derivative on measurement. Real plants add delay, noise and saturation.

Common misconceptions

  • Misconception: Overshoot is measured relative to the final value, not the setpoint, if there is steady-state error.
  • Misconception: Zero overshoot is not automatically good; it can mean a very slow response.