Skip to content
Tactiverge

Numerical stability and choosing a step size

See how a step that is too large can make a simulation blow up, understand why, fix oscillating systems with semi-implicit Euler, and learn a routine for choosing dt.

Lesson 5 of 6 · 30 min · Self-paced · Free

When a simulation explodes

You simulate a robot arm, run it for ten seconds of virtual time, and the joint angle reads 10³⁰ radians. Nothing physical caused this. The numerical method itself became unstable: tiny errors grew a little every step until they swamped the answer. Instability is one of the most common ways simulations fail, and it can be subtle, starting as a slow drift that looks almost physical. This lesson explains where it comes from and how to avoid it.

Accuracy and stability are different

  • Accuracy is how close each answer is to the truth. Inaccurate results are a bit wrong.
  • Stability is whether errors stay bounded as the simulation runs. Unstable results grow without limit and become meaningless.

A method can be stable but inaccurate (a coarse step that gets the shape roughly right) or, over a short run, accurate-looking but unstable (errors that are tiny now but doubling every few steps).

The simplest test: exponential decay

Take dy/dt = −k · y with k = 10 per second. The true solution decays smoothly to zero. One Euler step gives

y_next = y + (−k · y) · dt = (1 − k · dt) · y

So each step multiplies y by the same amplification factor, 1 − k · dt. Everything depends on that factor:

K_RATE = 10.0   # decay rate, per second: dy/dt = -10·y

for dt in [0.05, 0.15, 0.25]:
    y = 1.0
    values = []
    for _ in range(6):
        y = y + (-K_RATE * y) * dt      # one Euler step
        values.append(f"{y:8.3f}")
    print(f"dt = {dt:4.2f} (k·dt = {K_RATE * dt:.1f}):", " ".join(values))

Output:

dt = 0.05 (k·dt = 0.5):    0.500    0.250    0.125    0.062    0.031    0.016
dt = 0.15 (k·dt = 1.5):   -0.500    0.250   -0.125    0.062   -0.031    0.016
dt = 0.25 (k·dt = 2.5):   -1.500    2.250   -3.375    5.062   -7.594   11.391
  • With k · dt = 0.5 the factor is 0.5: smooth decay, roughly right.
  • With k · dt = 1.5 the factor is −0.5: the value still shrinks, but flips sign every step. The real system never goes negative, so this is badly inaccurate, though still stable.
  • With k · dt = 2.5 the factor is −1.5: every step makes the value 1.5 times larger and flips its sign. Unstable. A decaying system has turned into an exploding one.

The rule: Euler's method on this equation is stable only if |1 − k · dt| ≤ 1, which means dt ≤ 2 / k, and it avoids sign flips only if dt ≤ 1 / k. The faster the system's own dynamics (the larger k), the smaller the step must be. Systems that mix very fast and very slow behaviour, called stiff systems, force a tiny step even when you only care about the slow part, which is why special methods exist for them.

Oscillators: Euler always gains energy

Now take the spring–mass system from the previous lesson without damping. Its total energy, ½ m v² + ½ k x², should stay constant forever. With explicit Euler, one can show with a little algebra that every step multiplies the energy by exactly

1 + ω_n² · dt²

which is always greater than 1. With m = 0.5 kg, k = 20 N/m (ω_n² = 40) and dt = 0.01 s, the factor is 1.004 per step. That looks harmless, but over 1000 steps (10 s) it compounds to 1.004¹⁰⁰⁰ ≈ 54. No step size makes explicit Euler stable for an undamped oscillator. A smaller step only slows the growth. This is why the previous lesson needed dt = 0.0001 s.

The fix: semi-implicit Euler

A tiny change to the order of updates makes a huge difference. Update the velocity first, then use the new velocity to update the position:

M, K = 0.5, 20.0      # kg, N/m (no damping)
DT = 0.01             # s
STEPS = 1000          # 10 seconds

def energy(x, v):
    return 0.5 * M * v * v + 0.5 * K * x * x   # joules

def explicit_euler(x, v):
    a = -K * x / M
    return x + v * DT, v + a * DT          # both use OLD values

def semi_implicit_euler(x, v):
    a = -K * x / M
    v = v + a * DT                         # update velocity first...
    return x + v * DT, v                   # ...then position uses NEW v

for name, step in [("explicit", explicit_euler), ("semi-implicit", semi_implicit_euler)]:
    x, v = 0.10, 0.0
    e0 = energy(x, v)
    for _ in range(STEPS):
        x, v = step(x, v)
    print(f"{name:14s} energy after 10 s: {energy(x, v) / e0:7.3f} × start")

Output:

explicit       energy after 10 s:  54.164 × start
semi-implicit  energy after 10 s:   0.977 × start

Same equations, same step, same amount of work per step. Explicit Euler has inflated the energy 54-fold; semi-implicit Euler is within a few percent of the true value. If you keep running it, its energy wobbles slightly above and below the starting value (within about ±3.5% for this step) but never drifts away, even after thousands of seconds. This method, also called symplectic Euler, is stable for oscillators as long as ω_n · dt is below 2, and it is widely used in game physics and robotics simulators because it is as cheap as Euler but behaves far better for things that vibrate.

Choosing a step size: a routine

There is no universal correct dt, but there is a reliable procedure:

  1. Find the fastest timescale in the system: the shortest period of oscillation (2π / ω_n), or the shortest time constant (1 / k). Start with dt well below it, for example a twentieth or less.
  2. Check stability limits for your method, such as dt ≤ 2 / k for Euler on decay or ω_n · dt below 2 for semi-implicit Euler on an oscillator. Stay well inside them.
  3. Run a convergence test: halve dt and rerun. If the quantity you care about changes by less than your tolerance, the step is small enough. If not, halve again.
  4. Watch a conserved quantity such as energy where one exists. Steady growth in a system that should conserve energy is a warning sign.
  5. Record the dt you used and the result of your convergence test alongside any results you report.

Knowledge check

Check your understanding

  1. 1. For dy/dt = −20 · y, what is the largest step for which explicit Euler is stable?
  2. 2. Euler on a decay equation gives values 1, −0.5, 0.25, −0.125, … What does this show?
  3. 3. What is the only difference between explicit and semi-implicit Euler in this lesson?
  4. 4. You halve dt and an important result changes by 30%. What should you do?

Go further